Sulfur Compound Instruments
​​​​​​​​​​​​​​​​​​​​​ Conta​​​ct us
Traini​ng
Sales Contacts
Request a Quote
Terms & Conditions
​​ ​
​​

​Model T108​
with NumaView™ Software

Total Sulfur Analyzer​​
T108_TS_web_2020_jpg.jpg

 Features

 

  • Ranges: 0-50 ppb to 0-20,000 ppb, user selectable
  • Dual ranges and auto ranging
  • Large, vivid, and durable color graphics display with touch screen interface
  • Ethernet, RS-232, and (optional) USB com ports
  • Front panel USB connections for peripheral devices and firmware upgrades
  • 8 analog inputs (optional)
  • Adaptive signal filtering optimizes response time
  • Temperature & pressure compensation
  • Continuous Auto Zero Correction
  • Comprehensive internal data logging with programmable averaging periods
  • Ability to log virtually any operating parameter
  • Two-year warranty​
  • External converter not shown above​

 Downloads

  
  
  
06807H - MANUAL, OPERATORS, T100.pdfT100 Manual10796 KB
07268C - ADDENDUM, MANUAL, T108.pdfT108 Manual Addendum8424 KB
08296D - Addendum,  NumaView(TM)Software-for-Analyzers.pdfNumaView™ Software Addendum for Analyzers7097 KB
ESD Fundamentals - 04786.pdfFundamentals of Electro-Static Discharge (ESD)216 KB
NVS Remote Manual - 08492.pdfNumaView™ Software Remote User Guide867 KB
SAL000044D - T108.pdfT108 Specification808 KB
SAL000044E-CN T108.pdfT108规格 (Chinese Specification)5168 KB
SAL000076K - Environmental Instruments Overview.pdfEnvironmental Instruments Overview610 KB
T SERIES_6PG.BROCHURE_2018_web.pdfT Series with NumaView™ Software Brochure9567 KB

 Specifications

​​
Ranges Min: 0-50 ppb full scale
Max: 0-20,000 ppb full scale (selectable, dual range supported)
Measurement Units ppb, ppm, μg/m3, mg/m3 (selectable)
Zero Noise 50 ppt (RMS)
Span Noise 0.5% of reading (RMS) above 5 ppb
Lower Detectable Limit < 0.4 ppb
Zero Drift < 0.5 ppb/24 hours
Span Drift < 0.5% of full scale/24 hours
Response Time
< 120 seconds to 95%
Linearity 1% of full scale
Precision
0.5% of reading above 50 ppb
Sample Flow Rate 650 cc/min ±10%
Power Requirements 100V-120V, 220V-240V, 50/60 Hz
Analog Output Ranges 10V, 5V, 1V, 0.1V (selectable)
Recorder Offset ±10%
Included I/O 1 x Ethernet: 10/100Base-T
2 x RS232 (300-115,200 baud)
2 x USB device ports
8 x opto-isolated digital outputs
6 x opto-isolated digital inputs
4 x analog outputs
Optional I/O 1 x USB com port
1 x RS485
4 x digital alarm outputs
Multidrop RS232
3 x 4 - 20mA current outputs
Operating Temperature Range 5 - 40ºC (with US EPA Equivalency)
Dimensions (HxWxD) Analyzer: 7” x 17” x 23.5” (178 x 432 x 597 mm)
Converter: 7” x 17” x 23.5” (178 x 432 x 597 mm)
Weight



Specifications are subject to change without notice.
All specifications are based on constant conditions.​
Analyzer: 45 lbs (20.5 kg)
Converter: 20 lbs (9.1​ kg) ​​​



 Description


The Model T108 Total Sulfur analyzer is designed to measure mixed sulfur impurities, collectively referred to as Total Sulfides, in air or carbon dioxide gas.  Since there is no scrubber in the system, the instrument reading is the sum of the oxidized sulfur compounds and SO2.

The Model T108 consists of a modified Model T100 SO2 analyzer with special software and a Model 501TS high temperature thermal oxidizer.  Sulfur compounds are heated as they pass through the converter and oxidized into SO2.  When analyzing CO2, which generally contains no oxygen, approximately 6% O2 is added to the sample before entering the converter.  This dilution is corrected in the calibration procedure.

All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/0, and built-in data acquisition capability.  All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.

The Model T108 comes with NumaView Software. NumaView Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView Software.​